Fluke TiR Thermal Imager Building Inspection Camera |
Temperature |
Temperature Range
|
-20 °C to +100 °C (-4 °F to +212 °F)
|
Temperature measurement accuracy
|
± 5 °C or 5 % (at 25 °C nominal, whichever is greater)
|
Imaging performance |
Frequency |
9 Hz refresh rate
|
Resolution
|
160 X 120 Focal Plane Array, uncooled microbolometer
|
Thermal Sensitivity (NETD)
|
≤ 0.1 °C at 30 °C target temp. (100 mK)
|
Infrared spectral band
|
7.5 μm to 14 μm (long wave)
|
Visual (visible light) camera
|
Industrial performance 1.3 megapixel
|
Minimum focus distance
|
46 cm (approx. 18 in)
|
Standard infrared lens type |
Field of view 23 ° x 17 ° Spatial resolution (IFOV) 1.25 mRad Minimum focus distance 15 cm (approx. 6 in)
|
Focus mechanism
|
Manual, one-handed Smart Focus capability |
Image presentation |
Palettes - Standard |
Ironbow, Blue-Red, High Contrast, Grayscale
|
Picture-In-Picture |
Yes |
Fusion |
Yes |
Level and span
|
Smooth auto-scaling and manual scaling of level and span
|
Minimum span (in manual mode) |
2.5 °C (4.5 °F)
|
Minimum span (in auto mode)
|
5 °C (9 °F)
|
Image capture and data storage |
Voice Annotation |
Yes |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
Storage medium |
SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader (TiR32 and TiR1 only) |
File formats |
Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometic bitmap (.bmp) files |
Export file formats w/SmartView® software |
JPEG, JPG, JPE, JFIF, BMP, DIB, GIF, PNG, TIF, and TIFF |
Memory review |
Sequential image navigation and review |